In a vented roof foam can seal the openings and serve as an air barrier and a vapor retarder in addition to its insulating function.
How to insulate non vented roof.
Vented roofs provide the capacity for moisture to be removed from the underside of roof sheathing via convection currents in the vent cavity.
Because today we as an industry are insulating below the vented cavity as standard practice the building itself is no longer heating the cavity.
In this energy smart homes article senior editor martin holladay explains how to insulate a vented low slope shed roof using a combination of intake vents and cupolas.
In an un vented roof foam can serve as the air barrier and vapor retarder and prevent moisture from getting in to the roof cavities.
Cut and insert 1 or thicker high r foam insulation sheets r 8 per inch against the furring giving a 1 or greater air path between the insulation and the roof deck under the cathedral ceiling.
The three layers of foam help to seal air leaks but to make this assembly perform well you need to incorporate some unconventional details.
As we note in our blog post yes unvented roof assemblies can be insulated with fiberglass a wufi post the building code written for the foam industry does ask for air impermeable insulation or foam.
Foam insulation can play an important role in both vented and un vented roof assemblies.
The vented roof also gives a path for moisture in the air whether from outside or inside the home to escape the roof structure.
In warm climates zones 1 through 4 low density open cell spray foam insulation is the typical choice since it is vapor permeable and will allow drying of the exterior sheathing and roof framing if they happen to get wet via diffusion into the interior of the building.
With rigid foam above the sheathing and cellulose in the rafter cavities this roof is about r 63.
Air can move through the attic space freely and the floor of the attic is insulated to thermally separate the.
Using intello plus with thermal insulation provides the necessary air and vapor barrier needed to prevent structural damage.
You must meet the same minimum code requirements for the spray foam layer and the total assembly as for the rigid foam plus air permeable insulation approach.
Spray foam with air permeable insulation.
Rigid foam insulation installed above the roof assembly can create an energy smart roof.
Because of limited space between the roof sheathing and ceiling joists a low slope shed roof can be difficult to insulate properly.
A layer of spray polyurethane foam can be installed against the underside of the roof sheathing with the rest of the rafter cavity filled with air permeable insulation.
The typical vented roof has a vent at the lower eave and a vent at the higher.